NYC Hospital Supply Fan Retrofit

NYC Hospital Supply Fan Retrofit

Existing belt-driven centrifugal blowers inside a NYC hospital air handling unit before the EC fan array retrofit.
GRR HVAC technicians working on existing blower equipment during a hospital AHU supply fan replacement in NYC.
GRR HVAC technicians working on existing blower equipment during a hospital AHU supply fan replacement in NYC.
GRR Cooling Experts technicians installing direct-drive EC fans into the new supply fan array at a NYC hospital.
Existing belt-driven centrifugal blowers inside a NYC hospital air handling unit before the EC fan array retrofit.
GRR HVAC technicians working on existing blower equipment during a hospital AHU supply fan replacement in NYC.
GRR HVAC technicians working on existing blower equipment during a hospital AHU supply fan replacement in NYC.
GRR Cooling Experts technicians installing direct-drive EC fans into the new supply fan array at a NYC hospital.

Challenge

An existing air handling unit at a New York City hospital required modernization of its supply fan system. The retrofit involved replacing older belt-driven blower equipment with a direct-drive EC fan array while retaining the existing AHU structure.

The replacement required proper fan selection, mounting provisions, electrical connections, and control integration.

Retrofit Scope

GRR Cooling Experts completed the supply fan retrofit, including:

  • Removal of the existing belt-driven blowers and associated components

  • Fabrication and installation of a new galvanized steel mounting panel

  • Installation of nine direct-drive EC fans in a 3 × 3 arrangement

  • Installation of backdraft dampers

  • Electrical wiring and control panel connections

  • System startup

The overall project also included a separate return-side fan retrofit.

Supply Fan Array Specifications

  • Design airflow: 17,500 CFM

  • Design static pressure: 8.0 in. w.g.

  • Fan configuration: 9 direct-drive EC fans, 3 × 3 arrangement

  • Mounting panel: 16 GA galvanized steel

  • Fan model: GR31C-ZID.DG.CR

  • Control panel: Baikal Advanced panel specified with BACnet connectivity

Airflow and static pressure figures represent equipment design specifications.

Installation Video

The video below shows the supply-side retrofit, from removal of the existing blower equipment to installation of the new nine-fan EC array.

Watch the installation:

Result

The existing belt-driven supply blowers were replaced with a nine-fan direct-drive EC array integrated into the existing AHU.

The new configuration eliminates belts and pulleys from the supply fan drive and provides individual EC fan control capability. The new mounting panel, backdraft dampers, and electrical connections were incorporated into the existing installation.

Final measured airflow and static pressure results were not available for inclusion in this case study.

Project Partners

Special thanks to BAIKAL MECHANICAL for equipment support and ZIEHL-ABEGG for the EC fan technology.

GRR Cooling Experts specializes in HVAC retrofit engineering, fan array installations, and ventilation modernization for hospitals and other critical environments throughout the New York City metropolitan area.

GRR Cooling Experts Inc. : Reliable Air. Every Time.

Challenge

An existing air handling unit at a New York City hospital required modernization of its supply fan system. The retrofit involved replacing older belt-driven blower equipment with a direct-drive EC fan array while retaining the existing AHU structure.

The replacement required proper fan selection, mounting provisions, electrical connections, and control integration.

Retrofit Scope

GRR Cooling Experts completed the supply fan retrofit, including:

  • Removal of the existing belt-driven blowers and associated components

  • Fabrication and installation of a new galvanized steel mounting panel

  • Installation of nine direct-drive EC fans in a 3 × 3 arrangement

  • Installation of backdraft dampers

  • Electrical wiring and control panel connections

  • System startup

The overall project also included a separate return-side fan retrofit.

Supply Fan Array Specifications

  • Design airflow: 17,500 CFM

  • Design static pressure: 8.0 in. w.g.

  • Fan configuration: 9 direct-drive EC fans, 3 × 3 arrangement

  • Mounting panel: 16 GA galvanized steel

  • Fan model: GR31C-ZID.DG.CR

  • Control panel: Baikal Advanced panel specified with BACnet connectivity

Airflow and static pressure figures represent equipment design specifications.

Installation Video

The video below shows the supply-side retrofit, from removal of the existing blower equipment to installation of the new nine-fan EC array.

Watch the installation:

Result

The existing belt-driven supply blowers were replaced with a nine-fan direct-drive EC array integrated into the existing AHU.

The new configuration eliminates belts and pulleys from the supply fan drive and provides individual EC fan control capability. The new mounting panel, backdraft dampers, and electrical connections were incorporated into the existing installation.

Final measured airflow and static pressure results were not available for inclusion in this case study.

Project Partners

Special thanks to BAIKAL MECHANICAL for equipment support and ZIEHL-ABEGG for the EC fan technology.

GRR Cooling Experts specializes in HVAC retrofit engineering, fan array installations, and ventilation modernization for hospitals and other critical environments throughout the New York City metropolitan area.

GRR Cooling Experts Inc. : Reliable Air. Every Time.